Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | InputRange | Output | Isolation | ResponseTime | Accuracy | Voltage-Supply | MountingType | TerminationStyle | OperatingTemperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ENTUBE SE (500V 10V)TRANSDUCER VOLTAGE DIVIDER |
3,872 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±500V | ±10V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (500VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
3,517 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 500VAC | 0 ~ 7VAC | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (250VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
3,968 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 250VAC | 0 ~ 7VAC | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (150VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
3,289 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 150VAC | 0 ~ 7VAC | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (1500V 5V)TRANSDUCER VOLTAGE DIVIDER |
2,541 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±1500V | ±5V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (1000V 5V)TRANSDUCER VOLTAGE DIVIDER |
2,839 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±1000V | ±5V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (750V 5V)TRANSDUCER VOLTAGE DIVIDER |
2,569 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±750V | ±5V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
ENTUBE SE (300V 5V)TRANSDUCER VOLTAGE DIVIDER |
2,331 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±300V | ±5V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C |
![]() |
CR4860-500TRANSDUCER VOLTAGE 24VDC |
3,949 | - |
|
![]() Datasheet |
Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 500VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
![]() |
CR4860-50TRANSDUCER VOLTAGE 24VDC |
2,749 | - |
|
![]() Datasheet |
Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 50VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
![]() |
CR4860-150TRANSDUCER VOLTAGE 24VDC |
3,901 | - |
|
![]() Datasheet |
Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
![]() |
CR4860-250TRANSDUCER VOLTAGE 24VDC |
3,257 | - |
|
![]() Datasheet |
Bulk | CR4800 | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
|
CR4520-150TRANSDUCER VOLTAGE 24VDC |
2,581 | - |
|
![]() Datasheet |
Box | CR4500 | Active | True RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
![]() |
CR4520-50TRANSDUCER VOLTAGE 24VDC |
3,133 | - |
|
![]() Datasheet |
Bulk | CR4500 | Active | True RMS AC Voltage Transducer | 0 ~ 50VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C |
![]() |
ENCORE (5A)TRANSDUCER CURRENT SENS SHUNT 5A |
3,924 | - |
|
![]() Datasheet |
Box | Encore | Active | Current Transducer | 0 ~ 5A | ±100mV | - | 8ns | ±0.2% | - | Free Hanging (In-Line) | BNC | -35°C ~ 70°C |
![]() |
ENTUBE SE STD (500VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
2,220 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 500VAC | 0 ~ 7VAC | - | - | ±0.2% | - | - | BNC | -25°C ~ 70°C |
![]() |
ENTUBE SE STD (250VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
3,329 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 250VAC | 0 ~ 7VAC | - | - | ±0.2% | - | - | BNC | -25°C ~ 70°C |
![]() |
ENTUBE SE STD (150VAC 7VAC)TRANSDUCER VOLTAGE DIVIDER |
3,985 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | 0 ~ 150VAC | 0 ~ 7VAC | - | - | ±0.2% | - | - | BNC | -25°C ~ 70°C |
![]() |
ENTUBE SE STD (5000V)TRANSDUCER VOLTAGE DIVIDER |
3,939 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±5000V | ±5V | - | - | ±0.2% | - | - | BNC, SHV | -25°C ~ 70°C |
![]() |
ENTUBE SE STD (3000V)TRANSDUCER VOLTAGE DIVIDER |
3,738 | - |
|
![]() Datasheet |
Box | Entube SE | Active | Voltage Transducer | ±3000V | ±5V | - | - | ±0.2% | - | - | BNC, SHV | -25°C ~ 70°C |